1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 81
Alarm No.: 7D
Name: Safety observation error
Alarm content
The safety observation function detected an error.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
7D.1 Stop
observation
error
(1) During activation of
SOS function, the
position of the servo
motor has changed by
more than the SOS
allowance value set by
parameter.
Check that the actual
servo motor position is
higher than the setting
value of [Pr. PSA05].
The travel distance
of the servo motor is
larger than the
setting value in [Pr.
PSA05].
Review the alarm
level.
[A]
[B]
[GF]
The travel distance
of the servo motor is
smaller than the
alarm detection level.
Check (2).
(2) During activation of
SOS function, the servo
motor speed has
changed by larger than
the SOS allowance
value set by parameter,
and that state has
continued for longer
than the set time
(specified by [Pr.
PSA15]).
The actual servo
motor speed is higher
than the setting value
of [Pr. PSA04].
The servo motor
speed is higher than
the setting value in
[Pr. PSA04].
Review the
parameter setting.
The servo motor
speed is higher than
the setting value in
[Pr. PSA15] and
equal to or lower
than that in [Pr.
PSA04].
Check (3).
(3) During activation of
SOS function, the
speed command has
changed by larger than
the SOS allowance
value set by parameter,
and that state has
continued for longer
than the set time
(specified by [Pr.
PSA15]).
Check if the command
from the controller is
over the standstill
speed set in [Pr.
PSA04].
The command from
the controller is over
the setting valued in
[Pr. PSA04].
Check the operation
pattern.
The command from
controller is higher
than the setting
value in [Pr. PSA15]
and equal to or
lower than that in
[Pr. PSA04].
Check (4).
(4) An encoder is
malfunctioning.
Replace the servo
motor, and then check
the repeatability.
It is not repeatable.
Replace the servo
motor.
It is repeatable.
Check (5).
(5) The functional safety
unit is malfunctioning.
Replace the functional
safety unit, and then
check the
repeatability.
It is not repeatable.
Replace the
functional safety unit.
It is repeatable.
Check (6).
(6) The servo amplifier is
malfunctioning.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
motor.
It is repeatable.
Check (7).
(7) Something near the
device caused it.
Check the noise,
ambient temperature,
vibration, etc.
It has a failure.
Take
countermeasures
against its cause.
Summary of Contents for MELSERVO MR-J4-B-RJ Series
Page 7: ...2 MEMO ...
Page 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Page 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Page 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Page 171: ...MEMO ...