1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 72
Alarm No.: 70
Name: Load-side encoder initial communication error 1
Alarm content
An error occurred in the initial communication between the load-side encoder and servo amplifier.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
70.B Load-side
encoder initial
communication
- Process error
2
Check it with the check method for [AL. 70.A].
70.C Load-side
encoder initial
communication
- Process error
3
70.D Load-side
encoder initial
communication
- Process error
4
70.E Load-side
encoder initial
communication
- Process error
5
70.F Load-side
encoder initial
communication
- Process error
6
Alarm No.: 71
Name: Load-side encoder normal communication error 1
Alarm content
An error occurred in the communication between the load-side encoder and servo amplifier.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
71.1 Load-side
encoder normal
communication
- Receive data
error 1
(1) A load-side encoder
cable is malfunctioning.
Check if the load-side
encoder cable is
disconnected or
shorted.
It has a failure.
Repair or replace
the cable.
[A]
[B]
[WB]
[GF]
It has no failure.
Check (2).
(2) The external conductor
of the encoder cable is
not connected to the
ground plate of the
connector.
Check if it is
connected.
It is not connected.
Connect it correctly.
It is connected.
Check (3).
(3) The parameter setting
of communication
method is incorrect.
[A]: [Pr. PC44]
[B] [GF]: [Pr. PC26]
Check the parameter
setting.
The setting is
incorrect.
Set it correctly.
[A]
[B]
[GF]
The setting is
correct.
Check (4).
(4) The servo amplifier is
malfunctioning.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
[A]
[B]
[WB]
[GF]
It is repeatable.
Check (5).
(5) A load-side encoder is
malfunctioning.
Replace the load-side
encoder, and then
check the
repeatability.
It is not repeatable.
Replace the load-
side encoder.
It is repeatable.
Check (6).
(6) Something near the
device caused it.
Check the noise,
ambient temperature,
vibration, etc.
It has a failure.
Take
countermeasures
against its cause.
Summary of Contents for MELSERVO MR-J4-B-RJ Series
Page 7: ...2 MEMO ...
Page 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Page 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Page 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Page 171: ...MEMO ...