3. TROUBLESHOOTING FOR MR-CR55K(4) RESISTANCE REGENERATION CONVERTER UNIT
3 - 5
No.
Name/Description
Cause
Check method
Check result
Action
30 Regenerative
error
Permissible
regenerative
power of the
regenerative
resistor
(regenerative
option) is
exceeded.
The regenerative
resistor is
malfunctioning.
A regenerative
transistor in the
resistance
regeneration
converter unit is
malfunctioning.
(8) A
regenerative
transistor in the
resistance regeneration
converter unit is
malfunctioning.
Remove the
regenerative resistor
(regenerative option)
and then check if the
alarm occurs at power
on.
The alarm occurs.
Replace the
resistance
regeneration
converter unit.
The alarm does not
occur.
Check (9).
(9) Something near the
device caused it.
Check the noise,
ground fault, ambient
temperature, etc.
It has a failure.
Take
countermeasures
against its cause.
33 Overvoltage
The value of the
bus voltage
exceeded the
prescribed value.
200 V class: 400 V
DC or more 400 V
class: 800 V DC or
more
(1) The
regenerative
resistor (regenerative
option) is not used.
Check if the
regenerative resistor
(regenerative option)
is used.
It is not used.
Use the regenerative
resistor
(regenerative
option).
It is used.
Check (2).
(2) The setting of the
regenerative resistor
(regenerative option) is
incorrect.
Check the
regenerative resistor
(regenerative option)
and [Pr. PA01] setting
value.
The setting value is
incorrect.
Set it correctly.
It is set correctly.
Check (3).
(3)
The
regenerative
resistor (regenerative
option) is not
connected.
Check if the
regenerative resistor
(regenerative option)
is connected
correctly.
It is not connected
correctly.
Connect it correctly.
It is connected
correctly.
Check (4).
(4) Wire breakage of the
regenerative resistor
(regenerative option).
Measure the
resistance of the
regenerative resistor
(regenerative option).
The resistance is
abnormal.
Replace the
regenerative resistor
(regenerative
option).
The resistance is
normal.
Check (5).
(5)
The
regeneration
capacity is insufficient.
Set a longer
deceleration time
constant, and then
check the
repeatability.
It is not repeatable.
Use the regenerative
resistor
(regenerative option)
with larger capacity.
It is repeatable.
Check (6).
(6) Power supply voltage
high.
Check if the voltage
of the input power
supply is over the
prescribed value.
200 V class: 264 V AC
400 V class: 528 V AC
It is higher than the
prescribed value.
Reduce the power
supply voltage.
It is at the
prescribed value or
lower.
Check (7).
(7) A ground fault or short
occurred at the servo
motor power cable.
Check if only the
servo motor power
cable is shorted.
It is shorted.
Replace the servo
motor power cable.
It is not shorted.
Check (8).
(8) Something near the
device caused it.
Check the noise,
ambient temperature,
etc.
It has a failure.
Take
countermeasures
against its cause.
(9) Impedance at wirings
of L1/L2/L3 is high, and
leak current from servo
motor power cable is
large.
Check the impedance
at wirings of L1/L2/L3
and leak current from
servo motor power
cable.
Impedance at wirings
of L1/L2/L3 is high,
and leak current from
servo motor power
cable is large.
Use the regenerative
resistor
(regenerative
option).
Summary of Contents for MELSERVO MR-J4-B-RJ Series
Page 7: ...2 MEMO ...
Page 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Page 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Page 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Page 171: ...MEMO ...