1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 75
Alarm No.: 75
Name: Option card error 2
Alarm content
MR-J3-T10 came off.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
75.3 Option
card
connection error
(1) MR-J3-T10 came off.
Check if the MR-J3-
T10 is mounted
correctly.
It is not mounted
correctly.
Install it correctly.
[RJ010]
It is mounted
correctly.
Check (2).
(2)
MR-J3-T10
is
malfunctioning.
Replace the MR-J3-
T10, and then check
the repeatability.
It is not repeatable.
Replace the MR-J3-
T10.
It is repeatable.
Check (3).
(3) The servo amplifier is
malfunctioning.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
75.4 Option
card
disconnected
(1) MR-J3-T10 was not
connected correctly.
Check if the MR-J3-
T10 is mounted
correctly.
It is not mounted
correctly.
Install it correctly.
It is mounted
correctly.
Check (2).
(2)
MR-J3-T10
is
malfunctioning.
Replace the MR-J3-
T10, and then check
the repeatability.
It is not repeatable.
Replace the MR-J3-
T10.
It is repeatable.
Check (3).
(3) The servo amplifier is
malfunctioning.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
Alarm No.: 79
Name: Functional safety unit diagnosis error
Alarm content
A diagnosis of the functional safety unit failed.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
79.1 Functional
safety unit
power voltage
error
(1) The power supply of
the functional safety
unit is failure.
Check the installation
of the functional safety
unit.
It has a failure.
Install it correctly.
[A]
[B]
[GF]
It has no failure.
Check (2).
(2) The functional safety
unit is malfunctioning.
Replace the functional
safety unit, and then
check the
repeatability.
It is not repeatable.
Replace the
functional safety unit.
It is repeatable.
Check (3).
(3) The servo amplifier is
malfunctioning.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
It is repeatable.
Check (4).
(4) Something near the
device caused it.
Check the power
supply for noise.
It has a failure.
Take
countermeasures
against its cause.
79.2 Functional
safety unit
internal error
(1) The functional safety
unit is malfunctioning.
Replace the functional
safety unit, and then
check the
repeatability.
It is not repeatable.
Replace the
functional safety unit.
It is repeatable.
Check (2).
(2) Something near the
device caused it.
Check the power
supply for noise.
It has a failure.
Take
countermeasures
against its cause.
Summary of Contents for MELSERVO MR-J4-B-RJ Series
Page 7: ...2 MEMO ...
Page 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Page 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Page 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Page 171: ...MEMO ...