1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 103
Alarm No.: 9E
Name: CC-Link IE warning 2
Alarm content
The receive data of the CC-Link IE communication is abnormal.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
9E.1 CC-Link
IE
warning
(1) The
transmission
status of the CC-Link
IE communication is
abnormal.
Check the noise,
ambient temperature,
etc.
It has a failure.
Take
countermeasures
against its cause.
[RJ010]
[GF]
It has no failure.
Check (2).
(2) The Ethernet cable was
disconnected.
Check the Ethernet
cable connection.
It is disconnected.
Turn off the control
circuit power
supply of the servo
amplifier, and then
connect the
Ethernet cable.
It is connected.
Check (3).
(3) The wiring of the
Ethernet cable was
incorrect.
Check if the wiring of
Ethernet cable is
correct.
The wiring is incorrect. Wire it correctly.
The wiring is correct.
Check (4).
(4) An Ethernet cable was
disconnected.
Check if the Ethernet
cable is
malfunctioning.
It has a failure.
Replace the
Ethernet cable.
It has no failure.
Check (5).
(5)
Communication
with
the master station is
abnormal.
Check the setting of
[Pr. Po02] and [Pr.
Po03].
The setting value is
incorrect.
Review the
communication
settings.
[RJ010]
The setting value is
correct.
Check (6).
(6) The master station is
malfunctioning.
Check if the master
station is
malfunctioning.
It has a failure.
Replace the master
station.
[RJ010]
[GF]
Alarm No.: 9F
Name: Battery warning
Alarm content
Battery voltage for absolute position detection system decreased.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
9F.1 Low battery
(1) The battery is not
connected to CN4.
Check if the battery is
connected correctly.
It is not connected.
Connect it correctly. [A]
[B]
[WB]
[RJ010]
[GF]
It is connected.
Check (2).
(2) The battery voltage is
low. The battery is
consumed.
Check the battery
voltage with a tester.
When an MR-
BAT6V1BJ battery for
junction battery cable
was used, check the
voltage of the
connector (orange)
for servo amplifier.
It is less than 4.9 V
DC.
Replace the battery.
9F.2 Battery
degradation
warning
(1) The absolute position
storage unit has not
connected.
Check if the absolute
position storage unit is
connected correctly.
It is not connected.
Connect it correctly. [A]
[B]
[WB]
[GF]
Summary of Contents for MELSERVO MR-J4-B-RJ Series
Page 7: ...2 MEMO ...
Page 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Page 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Page 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Page 171: ...MEMO ...