1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 96
Alarm No.: 92
Name: Battery cable disconnection warning
Alarm content
Battery voltage for absolute position detection system decreased.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
92.1 Encoder
battery cable
disconnection
warning
(1) 1) When an MR-
BAT6V1SET(-A)
battery or MR-
BT6VCASE battery
case was used, the
battery was not
connected to CN4.
2) When an MR-
BAT6V1BJ battery
for junction battery
cable was used, the
battery was not
connected to both
CN4 and MR-
BT6VCBL03M
junction battery
cable.
Check if the battery is
connected correctly.
It is not connected.
Connect it correctly. [A]
[B]
[WB]
[RJ010]
[GF]
It is connected.
Check (2).
(2) A battery cable was
disconnected.
Check if the battery
cable is
malfunctioning.
It has a failure.
Replace or repair
the cable.
It has no failure.
Check (3).
(3) The battery voltage is
low. The battery is
consumed.
Check the battery
voltage with a tester.
When an MR-
BAT6V1BJ battery for
junction battery cable
was used, check the
voltage of the
connector (orange)
for servo amplifier.
It is less than 3.1 V
DC.
Replace the battery.
It is 3.1 V DC or
more.
Check (4).
(4) An encoder cable was
disconnected.
Check if the encoder
cable is
disconnected.
It is disconnected.
Replace or repair
the cable.
92.3 Battery
degradation
(1) The battery voltage is
low. The battery is
consumed.
Check the battery
voltage with a tester.
It is less than 3.0 V
DC.
Replace the battery.
It is 3.0 V DC or
more.
Check (2).
(2) The battery has
deteriorated.
Replace the battery,
and then check the
repeatability.
It is not repeatable.
Replace the battery.
Alarm No.: 93
Name: ABS data transfer warning
Alarm content
ABS data were not transferred.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
93.1 ABS
data
transfer
requirement
warning during
magnetic pole
detection
(1) The Z-phase was not
turned on at servo-on.
Check if the position
within one-revolution
is "0".
It is "0". (The Z-
phase was not
turned on.)
Turn on the Z-phase
and disable the
magnetic pole
detection. Always
make home position
setting again.
[A]
It is other than "0".
(The Z-phase was
turned on.)
Check (2).
(2) The magnetic pole
detection was
executed.
Check if the ABS data
is transferred during
the magnetic pole
detection.
The ABS data is
transferred.
Disable the magnetic
pole detection. After
that, cycle SON
(Servo-on) and
transfer the ABS
data.
Summary of Contents for MELSERVO MR-J4-B-RJ Series
Page 7: ...2 MEMO ...
Page 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Page 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Page 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Page 171: ...MEMO ...