1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 117
Description
Possible cause
Check result
Action
Target
The display shows "Ab".
Connection to MR-J4W3-_B
with software version A2 or
earlier was attempted in
0.222 ms communication
cycle.
Check if the communication
cycle on servo system
controller side is 0.222 ms.
Use them with 0.444 ms or
more communication cycle.
[WB]
MR-J4W3-_B was attempted
to use in fully closed loop
system.
Check if it was attempted to
use in fully closed loop
system.
MR-J4W3-_B does not
support the fully closed loop
control system. Use MR-J4-
_B_ or MR-J4W2-_B.
A SSCNET III cable was
disconnected.
Check if "Ab" is displayed in
the corresponding axis and
following axes.
Replace the SSCNET III
cable of the corresponding
axis.
[B]
[WB]
Check if the connectors
(CNIA, CNIB) are unplugged.
Connect it correctly.
The control circuit power
supply of the previous axis
servo amplifier is off.
Check if "Ab" is displayed in
the corresponding axis and
following axes.
Check the power of the servo
amplifier.
The amplifier-less operation
function of servo system
controller is enabled.
Check if the amplifier-less
operation function of servo
system controller is enabled.
Disable the amplifier-less
operation function.
The servo amplifier is
malfunctioning.
Check if "Ab" is displayed in
the corresponding axis and
following axes.
Replace the servo amplifier
of the corresponding axis.
An Ethernet cable was
disconnected.
Check if "Ab" is displayed in
the corresponding axis and
following axes.
Replace the Ethernet cable
of the corresponding axis.
[RJ010]
[GF]
The servo amplifier power
was switched on when the
master station was off.
Check the power of the
master station.
Turn on the power of the
master station.
Communication cycle does
not match.
Check the communication
cycle on the master station
side.
When using 8 axes or less:
0.888 ms
When using 16 axes or less:
1.777 ms
Set it correctly.
[RJ010]
Check the communication
cycle by referring to the
controller instruction manual.
Refer to the controller
instruction manual.
[GF]
MR-J3-T10 is malfunctioning. Replace the MR-J3-T10, and
then check the repeatability.
Replace the MR-J3-T10.
[RJ010]
The servo amplifier is
malfunctioning.
Replace the servo amplifier,
and then check the
repeatability.
Replace the servo amplifier.
[RJ010]
[GF]
The master station is
malfunctioning.
Replace the master station,
and then check the
repeatability.
Replace the master station.
Summary of Contents for MELSERVO MR-J4-B-RJ Series
Page 7: ...2 MEMO ...
Page 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Page 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Page 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Page 171: ...MEMO ...