1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 115
Alarm No.: F7
Name: Machine diagnosis warning
Alarm content
There is a possibility that the equipment connected with the servo motor is malfunctioning.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
F7.1
Vibration failure
prediction
warning
(1) The servo system is
unstable and
oscillating.
Check if the gain is
changed after the
vibration failure
prediction function is
enabled.
The gain was
changed.
Adjust the servo
gain with the auto
tuning. Set the
machine resonance
suppression filter.
[GF]
The gain was not
changed.
Check (2).
(2) The vibration during
servo motor operation
increased because of
deterioration of
equipment parts.
Check that the
vibration level during
servo motor operation
increased from that
during the initial
operation.
The vibration level
during servo motor
operation increased
by 5% or lower from
that during the initial
operation.
Set a larger
threshold
multiplication for
vibration failure
prediction ([Pr.
PF40] "_ _ x _") and
restart the
equipment.
The vibration level
during servo motor
operation increased
by 5% or higher
from that during the
initial operation.
Check and maintain
the equipment and
replace parts as
necessary.
F7.2 Friction
failure
prediction
warning
(1) Changes
in
environment affected
equipment friction.
Check that
environment
conditions such as
ambient temperature
has been changed
from that of the initial
operation.
The usage
environment has
been changed.
Reset the threshold
to set a new one.
The
usage
environment is not
changed.
Check (2).
(2)
Deterioration
of
equipment parts
affected equipment
friction.
Check that the friction
torque at rated speed
has been changed
from that of the initial
operation.
The friction torque
at rated speed is not
changed from that
of the initial
operation.
Set a larger
threshold
multiplication for
friction failure
prediction ([Pr. PF40]
"_ _ _ x") and restart
the equipment.
The friction torque
at rated speed has
been changed from
that of the initial
operation.
Check and maintain
the equipment and
replace parts as
necessary.
F7.3 Total
travel
distance failure
prediction
warning
(1) The servo motor total
travel distance exceeds
the threshold.
Check if the threshold
is set correctly.
The threshold is not
set correctly.
Set the parameters
so that the value of
"[Pr. PF34] × [Pr.
PF41]" is
approximately the
same as the rated
life and restart the
equipment.
The threshold is set
correctly.
Check the
equipment. After
replacing the
equipment, reset the
servo motor total
travel distance.
Summary of Contents for MELSERVO MR-J4-B-RJ Series
Page 7: ...2 MEMO ...
Page 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Page 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Page 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Page 171: ...MEMO ...