1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 64
Alarm No.: 66
Name: Encoder initial communication error (safety observation function)
Alarm content
The connected encoder is not compatible with the servo amplifier.
An error has occurred in the communication between an encoder and servo amplifier.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
66.1 Encoder
initial
communication
- Receive data
error 1 (safety
observation
function)
(1) An encoder cable is
malfunctioning.
Check if the encoder
cable is disconnected
or shorted.
It has a failure.
Replace or repair
the cable.
[A]
[B]
[GF]
It has no failure.
Check (2).
(2) The servo amplifier is
malfunctioning.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
It is repeatable.
Check (3).
(3) An encoder is
malfunctioning.
Replace the servo
motor, and then
check the
repeatability.
It is not repeatable.
Replace the servo
motor.
It is repeatable.
Check (4).
(4) Something near the
device caused it.
Check the noise,
ambient temperature,
vibration, etc.
It has a failure.
Take
countermeasures
against its cause.
66.2 Encoder
initial
communication
- Receive data
error 2 (safety
observation
function)
Check it with the check method for [AL. 66.1].
66.3 Encoder
initial
communication
- Receive data
error 3 (safety
observation
function)
66.7 Encoder
initial
communication
- Transmission
data error 1
(safety
observation
function)
66.9 Encoder
initial
communication
- Process error
1 (safety
observation
function)
(1) A servo motor with
functional safety is not
connected.
Check if a servo motor
with functional safety
is connected.
It is not a servo
motor with
functional safety.
Connect a servo
motor with
functional safety.
[A]
[B]
[GF]
It is a servo motor
with functional
safety.
Check (2).
(2) The functional safety
unit is malfunctioning.
Replace the functional
safety unit, and then
check the
repeatability.
It is not repeatable.
Replace the
functional safety unit.
It is repeatable.
Check (3).
(3) The servo amplifier is
malfunctioning.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
It is repeatable.
Check (4).
(4) An encoder is
malfunctioning.
Replace the servo
motor, and then
check the
repeatability.
It is not repeatable.
Replace the servo
motor.
It is repeatable.
Check (5).
(5) Something near the
device caused it.
Check the noise,
ambient temperature,
etc.
It has a failure.
Take
countermeasures
against its cause.
Summary of Contents for MELSERVO MR-J4-B-RJ Series
Page 7: ...2 MEMO ...
Page 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Page 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Page 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Page 171: ...MEMO ...