1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 89
Alarm No.: 8D
Name: CC-Link IE communication error
Alarm content
MR-J3-T10 came off.
An error occurred in CC-Link IE communication.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
8D.5 Master
station
setting error 2
(1) A reserved station has
been selected by the
master station, and the
cyclic communication
has stopped.
Check if a reserved
station is selected.
It is selected.
Cancel the
reserved station.
[RJ010]
8D.6 CC-Link
IE
communication
error 3
Check it with the check method for [AL. 8D.1].
8D.7 CC-Link
IE
communication
error 4
(1) The
transmission
status of the CC-Link IE
communication is
abnormal.
Check the noise,
ambient temperature,
etc.
It has a failure.
Take
countermeasures
against its cause.
[RJ010]
[GF]
It has no failure.
Check (2).
(2)
MR-J3-T10
is
malfunctioning.
Replace the MR-J3-
T10, and then check
the repeatability.
It is not repeatable.
Replace the MR-
J3-T10.
[RJ010]
It is repeatable.
Check (3).
(3) The servo amplifier is
malfunctioning.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
[RJ010]
[GF]
It is repeatable.
Check (4).
(4) The master station is
malfunctioning.
Check if the master
station is
malfunctioning.
It has a failure.
Replace the master
station.
8D.8 CC-Link
IE
communication
error 5
Check it with the check method for [AL. 8D.7].
8D.9 Synchronization
error 1
Check it with the check method for [AL. 8D.1].
8D.A Synchronization
error 2
Alarm No.: 8E
Name: USB communication error/serial communication error/Modbus-RTU communication error
Alarm content
A communication error occurred between the servo amplifier and a personal computer/controller.
An error occurred in USB communication, serial communication (Mitsubishi general-purpose AC servo
protocol), or Modbus-RTU communication.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
8E.1 USB
communication
receive
error/serial
communication
receive error
(1) The setting of the
personal computer, etc.
is incorrect.
Check the setting of
the personal
computer, etc.
It is incorrect.
Review the settings. [A]
[B]
[WB]
[RJ010]
[GF]
It is correct.
Check (2).
(2) A communication cable
is malfunctioning.
Check the
communication cable,
and then check the
repeatability.
It is not repeatable.
Replace the
communication
cable.
It is repeatable.
Check (3).
(3) The servo amplifier is
malfunctioning.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
8E.2 USB
communication
checksum
error/serial
communication
checksum error
(1) The setting of the
personal computer, etc.
is incorrect.
Check the setting of
the personal
computer, etc.
It is incorrect.
Review the settings.
Summary of Contents for MELSERVO MR-J4-B-RJ Series
Page 7: ...2 MEMO ...
Page 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Page 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Page 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Page 171: ...MEMO ...