![Mitsubishi Electric FR-F700PJ Series Instruction Manual Download Page 81](http://html.mh-extra.com/html/mitsubishi-electric/fr-f700pj-series/fr-f700pj-series_instruction-manual_239805081.webp)
Parameter list
Parameter list
72
Parameter List
L
ife diagnosis
255
Life alarm status display
(0 to 15)
1
0
255
3F
BF
2
256
Inrush current limit circuit life display
(0 to 100%)
1%
100%
256
40
C0
2
257
Control circuit capacitor life display
(0 to 100%)
1%
100%
257
41
C1
2
258
Main circuit capacitor life display
(0 to 100%)
1%
100%
258
42
C2
2
259
Main circuit capacitor life measuring
0, 1 (2, 3, 8, 9)
1
0
259
43
C3
2
—
260
PWM frequency automatic switchover
0, 1
1
1
260
44
C4
2
Power fail
u
re
stop
261
Power failure stop selection
0 to 2
1
0
261
45
C5
2
—
267
Terminal 4 input selection
0 to 2
1
0
267
4B
CB
2
—
268
Monitor decimal digits selection
0, 1, 9999
1
9999
268
4C
CC
2
—
269
Parameter for manufacturer setting. Do not set.
269
Parameter for manufacturer setting. Do not set.
—
295
Magnitude of frequency change setting
0, 0.01, 0.10, 1.00,
10.00
0.01
0
295
67
E7
2
Pass
word
function
296
Password lock level
1 to 6, 101 to 106, 9999
1
9999
296
68
E8
2
297
Password lock/unlock
1000 to 9998 (0 to 5,
9999)
1
9999
297
69
E9
2
—
298
Frequency search gain
0 to 32767, 9999
1
9999
298
6A
EA
2
—
299
Rotation direction detection selection
at restarting
0, 1, 9999
1
0
299
6B
EB
2
RS-485 communication
338
Communication operation command
source
0, 1
1
0
338
26
A6
3
339
Communication speed command
source
0 to 2
1
0
339
27
A7
3
340
Communication startup mode selection 0, 1, 10
1
0
340
28
A8
3
342
Communication EEPROM write
selection
0, 1
1
0
342
2A
AA
3
343
Communication error count
—
1
0
343
2B
AB
3
—
374
Overspeed detection level
0 to 400Hz, 9999
0.01Hz
9999
374
4A
CA
3
Second motor
const
ant
450
Second applied motor
0, 1, 9999
1
9999
450
32
B2
4
Remote
Output
495
Remote output selection
0, 1, 10, 11
1
0
495
5F
DF
4
496
Remote output data 1
0 to 4095
1
0
496
60
E0
4
—
502
Stop mode selection at communication error
0 to 3
1
0
502
02
82
5
Maintenance
503
Maintenance timer
0 (1 to 9998)
1
0
503
03
83
5
504
Maintenance timer alarm output set time
0 to 9998, 9999
1
9999
504
04
84
5
—
505
Speed setting reference
1 to 120Hz
0.01Hz
60Hz
505
05
85
5
Co
mmunication
549
Protocol selection
0, 1
1
0
549
31
B1
5
551
PU mode operation command source
selection
2, 4, 9999
1
9999
551
33
B3
5
—
552
Frequency jump range
0 to 30Hz, 9999
0.01Hz
9999
552
34
B4
5
PI
D
opera
tion
553
PID deviation limit
0 to 100%, 9999
0.1%
9999
553
35
B5
5
554
PID signal operation selection
0 to 3, 10 to 13
1
0
554
36
B6
5
Func-
tion
Parameter
Name
Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter
Remarks
Instruction Code
Control Mode-based
Correspondence Table
Parameter
Read
Write
Extended
Copy
Clear
All
clear
V/F
V/F
V/F
GP
MFVC
GP
MFVC
GP
MFVC
IPM
IPM
IPM
Summary of Contents for FR-F700PJ Series
Page 13: ...IX MEMO ...
Page 29: ...16 MEMO ...
Page 76: ...63 MEMO ...
Page 299: ...294 MEMO ...
Page 321: ...316 MEMO ...