Communication operation and setting
Fault history batch
clear
Write
HF4
H9696: Clears the fault history as a batch
4 digits
(A, C/D)
Parameter clear
All clear
Write
HFC
All parameters return to the initial values.
Whether to clear communication parameters or not can be selected
according to data. (
: Clear,
: Not clear)
for parameter clear, all clear, and communication
parameters.
When clear is executed for H9696 or H9966, communication-related
parameter settings also return to the initial values. When resuming
operation, set the parameters again.
Executing clear will clear the instruction code HEC, HF3, and HFF
settings. Only H9966 and H55AA (all parameter clear) are valid
during the password lock.
Turning OFF the power supply while clearing parameters with H5A5A or
H55AA also clears the communication parameter settings back to the initial
settings.
4 digits
(A, C/D)
Parameter
Read
H00 to H63
Refer to the instruction code
and write and/or read
parameter values as required.
When setting
Pr. 100
and later, link parameter extended setting must
be set.
Data format of
Pr. 37
read and write is E2 and A2
4 digits
(B, E/D),
6 digits
(B, E2/D)
Write
H80 to HE3
4 digits
(A, C/D),
6 digits
(A2, C/D)
Link parameter
extended setting
Read
H7F
Parameter description is changed according to the H00 to H09
settings.
For details of the settings, refer to the parameter instruction code
.
2 digits
(B, E1/D)
Write
HFF
2 digits
(A1, C/D)
Second parameter
changing
(instruction code
HFF = 1, 9)
Read
H6C
Calibration parameters are set. (Refer to the list of calibration
parameters on the next page.)
H00: Frequency (Writing of the gain frequency is available with
Pr. 125
(instruction code H99) and
Pr. 126
(instruction code H9A).)
H01: Parameter-set analog value
H02: Analog value input from terminal
2 digits
(B, E1/D)
Write
HEC
2 digits
(A1, C/D)
Multi command
Write/
Read
HF0
Available for writing 2 commands, and monitoring 2 items for reading
data (
for detail)
10 digits
(A3, C1/D)
In
vert
er m
o
del m
onit
o
r
Inverter
model
Read
H7C
Reading inverter model in ASCII code.
"H20" (blank code) is set for blank area
Example of FR-F740PJ
H46, H52, H2D, H46, H37, H34, H30, H50, H4A, H20 ... H20
20 digits
(B, E3/D)
Capacity
Read
H7D
Reading inverter capacity in ASCII code.
Data is read in increments of 0.1kW, and rounds down to 0.01kW
increments
"H20" (blank code) is set for blank area
Example
0.4K................. " 4" (H20, H20, H20, H20, H20, H34)
0.75K............... " 7" (H20, H20, H20, H20, H20, H37)
6 digits
(B, E2/D)
REMARKS
Set 65520 (HFFF0) as a parameter value "8888" and 65535 (HFFFF) as "9999".
For the instruction codes HFF, HEC and HF3, their values are held once written but cleared to zero when an inverter reset or all
clear is performed.
Item
Read/
Write
Instruction
Code
Data Definition
Number of
Data Digits
(Format)
Refer to page 227
for data format (A, A1, A2, A3, B, C, C1, D, E, E1, E2, E3)
The increment is 0.001 and the data format is E2 or A2 when the following conditions are met:
Pr. 37
= "0.01 to 9998,"
Pr. 144
= "2 to 10," and the
instruction code HFF = "01."
Clear Type
Data
Communication Pr.
Parameter clear
H9696
H5A5A
All parameter clear
H9966
H55AA