![Mitsubishi Electric FR-F700PJ Series Instruction Manual Download Page 216](http://html.mh-extra.com/html/mitsubishi-electric/fr-f700pj-series/fr-f700pj-series_instruction-manual_239805216.webp)
211
Selection of operation mode and operation location
4.19.3 Setting the frequency by the operation panel (
Pr. 79
= 3)
POINT
Switch ON the STF(STR) signal to give a start command.
Use the operation panel (
) to give a frequency command.
Set "3" (External/PU combined operation mode 1) in
Pr. 79
.
Operation
example
Operate at 30Hz.
Operation Display
1.
Screen at power-ON
The monitor display appears.
2.
Change the
Pr. 79
setting to "3". (Refer to page
for change of the setting.)
[PU] indicator and [EXT] indicator are lit.
3.
Turn
to show the frequency you want to set.
The frequency flickers for about 5s.
4.
While the value is flickering, press
to set the
frequency.
After the value flickered for about 3s, the display
returns to "
" (monitor display).
(If you do not press
, the value flickers for about
5s and the display then returns to "
" (0.00Hz).
At this time, return to "Step 3" and set the frequency
again.)
Flicker...frequency setting complete!!
The monitor display appears after 3s.
5.
Start
acceleration
constant speed
Turn the start switch (STF or STR) ON.
The frequency value on the display increases in
Pr. 7
Acceleration time, and
"
" (30.00Hz) appears.
[RUN] indicator is lit during forward rotation operation
and flickers during reverse rotation operation.
6.
To change the set frequency, perform the operation in above steps 3 and 4. (Starting from the previously set frequency.)
7.
Deceleration
stop
Turn OFF the start switch (STF or STR). The
frequency value on the indication decreases in
Pr. 8
Deceleration time,
and the motor stops rotating with
"
" (0.00Hz) displayed.
[RUN] turns OFF.
REMARKS
Pr. 178 STF terminal function selection
must be set to "60" (or
Pr. 179 STR terminal function selection
must be set to "61").
(all are initial values)
When
Pr. 79 Operation mode selection
is set to "3", multi-speed operation
is also valid.
Pressing
to stop the motor and the display shows
.
1. Turn the start switch (STF or STR) OFF.
2. The display can be reset by
.
SD
STF
STR
Inverter
Operation
panel
Forward rotation start
Reverse rotation start
[Connection diagram]
Flickers for about 5s
Forward
rotation
Reverse
rotation
ON
Forward
rotation
Reverse
rotation
OFF
Stop