344
Appendix 2 Options and products available on the market
Name
Model
Applications, Specifications, etc.
Applicable
Inverter
S
tan
d-
a
lo
n
e t
ype
Parameter unit
(Eight languages)
FR-PU07
FR-PU04
Interactive parameter unit with LCD display
Applicable for all
models
Enclosure surface operation
panel
FR-PA07
This operation panel enables inverter operation and monitoring
of frequency, etc. from the enclosure surface
Applicable for all
models
Parameter unit
connection cable
FR-CB20
Cable for connection of operation panel or parameter unit
indicates a cable length. (1m, 3m, 5m)
Applicable for all
models
DIN rail attachment
FR-UDA01 to 03
Attachment for installation on DIN rail
For the 3.7K or
lower
AC reactor
FR-HAL
For harmonic current reduction and inverter input power factor
improvement
Applicable for the
certain capacities
DC reactor
FR-HEL
Applicable for the
certain capacities
EMC Directive compliant EMC
filter
SF
FR-E5NF
An EMC filter that complies with the EMC Directive
(EN61800-3 C3).
Applicable for the
certain capacities
EMC filter installation
attachment
FR-A5AT03
An attachment used to mount an EMC compliant EMC filter
(SF) to an inverter.
Applicable for the
certain capacities
FR-AAT02
FR-E5T
Radio noise filter
FR-BIF(H)
For radio noise reduction (connect to the input side)
Applicable for all
models
Line noise filter
FR-BSF01
FR-BLF
For line noise reduction
Applicable for all
models.
Brake resistor
MRS type,
MYS type
For increasing the regenerative braking capability (permissible
duty 3%/6%ED)
200V: applicable
for the certain
capacities
High-duty brake resistor
FR-ABR
For increasing the regenerative braking capability (permissible
duty 10%/ 6%ED)
Applicable for the
certain capacities.
Brake unit
Resistor unit
Discharging resistor
FR-BU2
FR-BR
GZG, GRZG type
For increasing the braking capability of the inverter (for high-
inertia load or negative load)
Brake unit, electrical-discharge resistor and resistor unit are
used in combination
Applicable for the
certain capacities
Power regeneration common
converter
Stand-alone reactor dedicated
for FR-CV
FR-CV
FR-CVL
Unit which can return motor-generated braking energy back to
the power supply in common converter system
Applicable for the
certain capacities
High power factor converter
FR-HC2
The high power factor converter switches the converter section
on/off to reshape an input current waveform into a sine wave,
greatly suppressing harmonics. (Used in combination with the
standard accessory.)
Applicable for the
certain capacities
Surge voltage suppression
filter
FR-ASF-H
Filter for suppressing surge voltage on motor
400V: applicable
for the certain
capacities
FR-BMF-H
400V: applicable
for the 5.5K or
higher
Summary of Contents for FR-F700PJ Series
Page 13: ...IX MEMO ...
Page 29: ...16 MEMO ...
Page 76: ...63 MEMO ...
Page 299: ...294 MEMO ...
Page 321: ...316 MEMO ...