Typical Configurations
37
CX/CXI CONTROLLER
FEATURE/
RESOURCE
VALUE/QUANTITY NOTES
RTC processor
266 MHz
This processor is listed as 300 MHz in the Engineering Tool.
Memory (RAM)
512 MB
IP Users and
Devices (Including
SIP Users)
100
Up to 16 IP devices may be connected directly to the powered
Ethernet ports on the front of the CXi cabinet.
Maximum 100 IP users.
TDM Devices
150
ONS devices only. DNIC devices are not supported on the CX.
Total Devices
150
ACD users
(active agents)
50
To install the maximum number of ACD users will require the
maximum number of digital trunks and DSP resources.
Echo canceller
channels/
IP gateway (E2T)
10 (default)
64 (max)
Echo cancellation is done in one DSP for the basic system. The
addition of more DSP devices can add another 10 channels, and each
T1/E1 combo module provides 32 channels of hardware echo
cancellation. (See Table 19 on page 54 for complete details.)
Conference
channels
30
Conference channels in the CX are allocated based on the number of
available DSP devices at start-up. The base system will have 9
channels (e.g. three 3-party conferences) and larger systems will
have 30 channels. Each conference may have up to eight members,
but the total cannot exceed the allowed maximum.
Voice Mail
16
The maximum allowed number of voice mail ports is also fixed by the
number of DSP devices installed. The base system allows up to 4
ports and, with increased DSP resources, up to 16.
Compression
channels
64
G.729a compression is not a standard offering on base systems.
Additional DSP resources are needed to achieve the values shown.
Compression is added in blocks of 8 bi-directional channels on Quad
DSP and DSP II modules only.
T.38
16
Record-a-Call
8
Every Record-a-Call session uses a conference resource and a voice
mail session from the available pool. The maximum number of
simultaneous sessions supported is 8, but may be limited to less than
this by the available resources.
CIM ports
3
One Quad CIM card can be installed, but only the first 3 ports will be
functional.
ASUs supported
3
Up to 3 external ASU and ASU II cabinets can be installed.
LS trunks (in ASU)
36
Up to 12 on internal AMB/AOB, and 24 in external ASU.
IP networking
yes
The system can support a maximum of 2000 programmed IP trunks,
but the number which can be used at any one time will be limited by
other resources.
Page 1 of 2
Summary of Contents for MiVOICE BUSINESS
Page 1: ...Mitel MiVoice Business RELEASE 7 2 ENGINEERING GUIDELINES ...
Page 15: ...Chapter 1 ABOUT THIS DOCUMENT ...
Page 16: ......
Page 22: ...Engineering Guidelines 8 ...
Page 23: ...Chapter 2 SYSTEM OVERVIEW ...
Page 24: ......
Page 28: ...Engineering Guidelines 14 ...
Page 29: ...Chapter 3 TYPICAL CONFIGURATIONS ...
Page 30: ......
Page 73: ...Chapter 4 PHONES AND VOICE APPLICATIONS ...
Page 74: ......
Page 95: ...Phones and Voice Applications 81 Figure 9 ICP Connection Paths and Limitations ...
Page 100: ...Engineering Guidelines 86 ...
Page 101: ...Chapter 5 POWER ...
Page 102: ......
Page 128: ...Engineering Guidelines 114 ...
Page 129: ...Chapter 6 PERFORMANCE ...
Page 130: ......
Page 135: ...Chapter 7 APPLICATIONS ...
Page 136: ......
Page 142: ...Engineering Guidelines 128 ...
Page 143: ...Chapter 8 EMERGENCY SERVICES ...
Page 144: ......
Page 151: ...Chapter 9 IP NETWORKING ...
Page 152: ......
Page 167: ...Chapter 10 LICENSING ...
Page 168: ......
Page 183: ...Chapter 11 BANDWIDTH CODECS AND COMPRESSION ...
Page 184: ......
Page 209: ...Chapter 12 NETWORK CONFIGURATION CONCEPTS ...
Page 210: ......
Page 244: ...Engineering Guidelines 230 ...
Page 245: ...Chapter 13 NETWORK CONFIGURATION SPECIFICS ...
Page 246: ......
Page 309: ...Appendix A CAT 3 WIRING ...
Page 310: ......
Page 315: ...CAT 3 Wiring 301 Figure 55 CX MX MXe AX and LX Minimum Cable Standard ...
Page 316: ...Engineering Guidelines 302 ...
Page 317: ...Appendix B INSTALLATION EXAMPLES ...
Page 318: ......
Page 335: ...Appendix C LLDP AND LLDP MED CONFIGURATION EXAMPLES ...
Page 336: ......
Page 347: ...Appendix D VOIP AND VLANS ...
Page 348: ......
Page 353: ...Appendix E VOIP SECURITY ...
Page 354: ......
Page 381: ... ...