Engineering Guidelines
94
OPTIONS FOR IP PHONE POWERING
Table 32: IP Phone Power Options
PHONES
IN-LINE
ETHERNET
AC POWER
ADAPTER (48
VDC LAN)
AC
POWER
ADAPTER
(24 VDC)
POWER
DONGLE
(CISCO-C
OMPLIANT
)
802.3AF
MID-SPAN
POWER
HUB
802.3AF
SPARE
PAIR
POWER
802.3AF
SIGNAL
(PHANTOM
) PAIR
POWER
802.3AB
(LLDP-MED
SIGNALLIN
G)
SUPPORT
5001
Yes
No
Yes
Yes
Yes
Yes
No
5005
Yes
No
Yes
Yes
Yes
Yes
No
5055 (SIP)
Yes
Yes
Yes
Yes
Yes
Yes
No
5010
Yes
Yes
Yes
Yes
Yes
Yes
No
5020
Yes
Yes
Yes
Yes
Yes
Yes
No
5201
Yes
No
Yes
Yes
Yes
Yes
No
5205
Yes
No
Yes
Yes
Yes
Yes
No
5207
Yes
No
Yes
Yes
Yes
Yes
No
5212
Yes
No
Yes
Yes
Yes
Yes
Yes
5215
Yes
No
Yes
Yes
Yes
Yes
No
5215 Dual
Mode
Yes
No
Yes
Yes
Yes
Yes
Yes
5220
Yes
Yes
Yes
Yes
Yes
Yes
No
5220 Dual
Mode
Yes
Yes
Yes
Yes
Yes
Yes
Yes
5224
Yes
Yes
Yes
Yes
Yes
Yes
Yes
5230
Yes
No
Yes
Yes
Yes
Yes
No
5235
Yes
No
Yes
Yes
Yes
Yes
Yes
5140
Yes
Yes
Yes
Yes
Yes
Yes
No
5240
Yes
Yes
Yes
Yes
Yes
Yes
No
5302
Yes
No
No
Yes
Yes
Yes
No
5304
Yes
No
No
Yes
Yes
Yes
Yes
5312
Yes
No
Yes
Yes
Yes
Yes
Yes
5324
Yes
No
Yes
Yes
Yes
Yes
Yes
5320
Yes
No
No
Yes
Yes
Yes
Yes
5320e
Yes
No
No
Yes
Yes
Yes
Yes
5330
Yes
No
Yes
Yes
Yes
Yes
Yes
5330e
Yes
No
Yes
Yes
Yes
Yes
Yes
5340
Yes
No
Yes
Yes
Yes
Yes
Yes
5340e
Yes
No
Yes
Yes
Yes
Yes
Yes
5360
Yes, but the
only power
supply
approved for
use is: Mitel
Part #
51015131)
No
No
Yes
(Power Hub
must
support
Gigabit
Ethernet
and must
be 802.3af
compliant)
No
Yes (Notes
2 and 3)
Yes
5505
Yes
No
No
Yes
Yes
Yes
Yes
5485 IP Pager
No
Yes
No
No
No
No
No
5540
Yes
No
No
Yes
Yes
Yes
Yes
Page 1 of 2
Summary of Contents for MiVOICE BUSINESS
Page 1: ...Mitel MiVoice Business RELEASE 7 2 ENGINEERING GUIDELINES ...
Page 15: ...Chapter 1 ABOUT THIS DOCUMENT ...
Page 16: ......
Page 22: ...Engineering Guidelines 8 ...
Page 23: ...Chapter 2 SYSTEM OVERVIEW ...
Page 24: ......
Page 28: ...Engineering Guidelines 14 ...
Page 29: ...Chapter 3 TYPICAL CONFIGURATIONS ...
Page 30: ......
Page 73: ...Chapter 4 PHONES AND VOICE APPLICATIONS ...
Page 74: ......
Page 95: ...Phones and Voice Applications 81 Figure 9 ICP Connection Paths and Limitations ...
Page 100: ...Engineering Guidelines 86 ...
Page 101: ...Chapter 5 POWER ...
Page 102: ......
Page 128: ...Engineering Guidelines 114 ...
Page 129: ...Chapter 6 PERFORMANCE ...
Page 130: ......
Page 135: ...Chapter 7 APPLICATIONS ...
Page 136: ......
Page 142: ...Engineering Guidelines 128 ...
Page 143: ...Chapter 8 EMERGENCY SERVICES ...
Page 144: ......
Page 151: ...Chapter 9 IP NETWORKING ...
Page 152: ......
Page 167: ...Chapter 10 LICENSING ...
Page 168: ......
Page 183: ...Chapter 11 BANDWIDTH CODECS AND COMPRESSION ...
Page 184: ......
Page 209: ...Chapter 12 NETWORK CONFIGURATION CONCEPTS ...
Page 210: ......
Page 244: ...Engineering Guidelines 230 ...
Page 245: ...Chapter 13 NETWORK CONFIGURATION SPECIFICS ...
Page 246: ......
Page 309: ...Appendix A CAT 3 WIRING ...
Page 310: ......
Page 315: ...CAT 3 Wiring 301 Figure 55 CX MX MXe AX and LX Minimum Cable Standard ...
Page 316: ...Engineering Guidelines 302 ...
Page 317: ...Appendix B INSTALLATION EXAMPLES ...
Page 318: ......
Page 335: ...Appendix C LLDP AND LLDP MED CONFIGURATION EXAMPLES ...
Page 336: ......
Page 347: ...Appendix D VOIP AND VLANS ...
Page 348: ......
Page 353: ...Appendix E VOIP SECURITY ...
Page 354: ......
Page 381: ... ...