LCD Status Messages
21
E2010
Memory not detected.
Inspect DIMMs.
No memory was detected
in the appliance.
Install memory or
reseat the memory
modules. See
E2011
Memory configuration
failure. Check DIMMs.
Memory detected, but is
not configurable. Error
detected during memory
configuration.
See
E2012
Memory configured
but unusable. Check
DIMMs.
Memory configured, but
is unusable.
See
E2013
BIOS unable to shadow
memory. Check
DIMMs.
The system BIOS failed
to copy its flash image
into memory.
See
E2014
CMOS RAM failure.
Power cycle AC.
CMOS failure. CMOS
RAM not functioning
properly.
Remove AC power to
the appliance for 10
seconds and restart the
appliance.
If the problem persists,
see
E2015
DMA Controller
failure. Power cycle
AC.
DMA controller failure.
Remove AC power to
the appliance for 10
seconds and restart the
appliance.
If the problem persists,
see
E2016
Interrupt Controller
failure. Power cycle
AC.
Interrupt controller
failure.
Remove AC power to
the appliance for 10
seconds and restart the
appliance.
If the problem persists,
see
E2017
Timer refresh failure.
Power cycle AC.
Timer refresh failure.
Remove AC power to
the appliance for 10
seconds and restart the
appliance.
If the problem persists,
see
Table 4
LCD Status Messages (Continued)
Code
Text
Cause
Corrective Actions