About Your Appliance
22
1
E2018
Programmable Timer
error. Power cycle AC.
Programmable interval
timer error.
Remove AC power to
the appliance for 10
seconds and restart the
appliance.
If the problem persists,
see
E2019
Parity error. Power
cycle AC.
Parity error.
Remove AC power to
the appliance for 10
seconds and restart the
appliance.
If the problem persists,
see
E201A
SuperIO failure. Power
cycle AC.
SIO failure.
Remove AC power to
the appliance for 10
seconds and restart the
appliance.
If the problem persists,
see
E201B
Keyboard Controller
error. Power cycle AC.
Keyboard controller
failure.
Remove AC power to
the appliance for 10
seconds and restart the
appliance.
If the problem persists,
see
E201C
SMI initialization
failure. Power cycle
AC.
System management
interrupt (SMI)
initialization failure.
Remove AC power to
the appliance for 10
seconds and restart the
appliance.
If the problem persists,
see
E201D
Shutdown test failure.
Power cycle AC.
BIOS shutdown test
failure.
Remove AC power to
the appliance for 10
seconds and restart the
appliance.
If the problem persists,
see
E201E
POST memory test
failure. Check DIMMs.
BIOS POST memory test
failure.
See
If the problem persists,
see
Table 4
LCD Status Messages (Continued)
Code
Text
Cause
Corrective Actions
Summary of Contents for RazorSafe 700
Page 10: ...4 Preface ...
Page 32: ...About Your Appliance 26 1 ...
Page 96: ...Jumpers and Connectors 90 B ...