About Your Appliance
16
1
E141F
CPU # protocol error.
Power cycle AC.
The system BIOS has
reported a processor
protocol error.
Remove AC power to
the appliance for 10
seconds and restart the
appliance.
If the problem persists,
see
E1420
CPU Bus parity error.
Power cycle AC.
The system BIOS has
reported a processor bus
parity error.
Remove AC power to
the appliance for 10
seconds and restart the
appliance.
If the problem persists,
see
E1422
CPU # machine check
error. Power cycle AC.
The system BIOS has
reported a machine
check error.
Remove AC power to
the appliance for 10
seconds and restart the
appliance.
If the problem persists,
see
E1610
Power Supply # (###
W) missing. Check
power supply.
Specified power supply
was removed or is
missing from the
appliance.
See
E1614
Power Supply # (###
W) error. Check power
supply.
Specified power supply
has failed.
See
E1618
Predictive failure on
Power Supply # (###
W). Check PSU.
A power supply fan
failure, an over-
temperature condition,
or power supply
communication error has
caused the predictive
warning of an impending
power supply failure.
See
E161C
Power Supply # (###
W) lost AC power.
Check PSU cables.
Specified power supply is
attached to the
appliance, but it has lost
its AC input.
Check the AC power
source for the specified
power supply. If the
problem persists, see
Troubleshooting Power
Supplies
Table 4