LCD Status Messages
23
E2020
CPU configuration
failure. Check screen
message.
Processor configuration
failure.
Check screen for
specific error messages.
See
E2021
Incorrect memory
configuration.
Incorrect memory
configuration.
Check screen for
specific error messages.
See
E2022
General failure during
POST. Check screen
message.
General failure after
video.
Check screen for
specific error messages.
E2023
BIOS unable to mirror
memory. Check
DIMMs.
The system BIOS could
not enable memory
mirroring because of a
faulty memory module
or an invalid memory
configuration.
See
E2110
Multibit Error on
DIMM ##. Reseat
DIMM.
The memory module in
slot ## has had a multi-
bit error (MBE).
See
E2111
SBE log disabled on
DIMM ##. Reseat
DIMM.
The system BIOS has
disabled memory single-
bit error (SBE) logging
and will not log any
more SBEs until the
appliance is rebooted. ##
represents the memory
module implicated by the
BIOS.
Remove AC power to
the appliance for 10
seconds and restart the
appliance.
If the problem persists,
see
E2113
Mem mirror OFF on
DIMM ## & ##.
Power cycle AC.
The system BIOS has
disabled memory
mirroring because it has
determined one half of
the mirror has had too
many errors. ## & ##
represents the memory
module pair implicated
by the BIOS.
Remove AC power to
the appliance for 10
seconds and restart the
appliance.
If the problem persists,
see
I1910
Intrusion detected.
Check chassis cover.
appliance cover has been
removed.
Information only.
Table 4
LCD Status Messages (Continued)
Code
Text
Cause
Corrective Actions