FrameMaker Ver.5.5E(PC) EP3000/EP3010 DIS/REASSEMBLY, ADJUSTMENT
98.05.29
D-53
✽
Requirement
(5) Adjustment of the Multi Bypass Table Reference Position
•
Ready a test chart (A3 or 11"
×
17") as shown on the
left.
Draw a line on the chart at a point 20 mm from the
right edge as shown.
•
Dimension A on the copy should measure
20 ± 2.0 mm.
1074D089
1. Place the test chart face down on the Original
Glass and align its rear left corner with the
marker on the Original Width Scale on the left side
of the platen.
Then, lower the Original Cover.
2. Using the Multi Bypass Table, make two full size
copies.
3. Using the second copy, compare the position of the
reference line on the copy with that on the test
chart.
4. If the line does not meet the requirement, loosen
the three screws that secure the Multi Bypass
Table and move the Table as necessary in the
direction of the arrows.
NOTE
If dimension A on the copy is smaller than 18 mm,
move the Table to the front. If it is more than 22 mm,
move the Table to the rear.
When an Automatic or Duplexing Document Feeder is
mounted, it involves changing the Original Glass. This
in turn results in the position of the Original Length
Scale being slightly shifted toward the rear. This is cor-
rected by installing the Original Positioning Plate.
1151D024AA