FrameMaker Ver.5.5E(PC) EP3000/EP3010 DIS/REASSEMBLY, ADJUSTMENT
98.05.29
D-47
40-2.ADJUSTMENT REQUIREMENTS LIST
Adjustment Item
Requirements
Adjusting Point
Ref.
Page
Optimum Exposure Setting
in the Manual Exposure
Mode
Kodak Gray Scale:
no image of the 1st step,
faint image of the 2nd
step
Control panel
D-50
Optimum Exposure Setting
in the Auto Exposure
Mode
Control panel
D-49
Multi Bypass Table
Reference Position
(
×
1.000) 20 ± 2 mm
Multi Bypass Table
D-53
1st Drawer Reference
Position
(
×
1.000) 20 ± 2 mm
Drawer Front Panel
D-54
2nd Drawer Reference
Position
(
×
1.000) 20 ± 2 mm
Drawer Front Panel
D-54
Full Size Leading Edge
Registration
(
×
1.000) 20 ± 1.5 mm
Control panel
D-57
Enlargement Leading
Edge Registration
(
×
2.000) 40 ± 3 mm
Control panel
D-61
Reduction Leading Edge
Registration
(
×
0.500) 10 ± 1.5 mm
Control panel
D-59
Image Leading Edge
Erase Width
1.0 to 6.5 mm
Control panel
D-62
Image Trailing Edge Erase
Width
2.0 to 3.0 mm
Control panel
D-64
Image Erase Lamp
Position
0.5
mm
Adjusting Screw for
Image Erase Lamp
position
D-66
Adjustment of the Original
Size Detecting Board
Control panel
D-70
+0.5
–0