FrameMaker Ver.5.5E(PC) EP3000/EP3010 DIS/REASSEMBLY, ADJUSTMENT
98.05.29
D-70
✽
Important
•
This adjustment must be made after the Original Size Detecting Board has been
replaced.
(4) Adjustment of the Original Size Detecting Board
1. Lower the Original Cover with no paper on the
Original Glass.
1139D228AA
2. On the control panel, press the User Mode key,
Meter Count key, Stop key, 10-keys “0”, 10-keys
“0”, Stop key, 10-keys “0”, and 10-keys “1”, in that
order, to set the copier into the Tech. Rep. Mode.
3. Touch “Function”.
4. Touch “F7 Orig. Sensor”.
1173D025CA
5. Press the Start Key to let the copier make the
adjustment.
NOTE
During the adjustment, the Start Key is lit up orange.
It turns to green as soon as the adjustment is com-
pleted.
(It takes about 2 sec. to make the adjustment.)
6. After the adjustment has been made, press the
Panel Reset Key twice (or turn OFF the Power
Switch) to return the copier back into the normal
mode.
1149D095CA