FrameMaker Ver.5.5E(PC) EP3000/EP3010 GENERAL, MECHANICAL/ELECTRICAL
98.06.10
M-5
1173SBM0400A
✽
Numbers given in rectangles
in the following flowchart are timer values in seconds.
4
SEQUENTIAL EXPLANATION
ON
DC24V for Drum heating (Power Supply Unit)
ON
Drum Dehumidifying
Heater
Paper Dehumidifying
Heater
ON
Only when Dehumidifying
Switch is ON
A The power cord is plugged into the outlet.
Power cord is plugged in.
ON
DC5V (Power Supply Unit)
ON
DC24V (Power Supply Unit)
ON
Control panel
ON
The Cooling Fan turns at full speed.
The Cooling Fan turns at half speed.
Fusing Heater Lamp
ON
ON
ON
Scanner Reference Position Sensor
✽
If the Scanner is not at the home position, Scanner Motor is
energized to move the Scanner to the home position.
Lens Reference Position Sensor
✽
If the Lens is not at the home position, Lens Motor is
energized to move the Lens to the home position.
ON
Mirror Reference Position Sensor
✽
If the 4th Mirror is not at the home position, Mirror Motor is
energized to move the Mirror to the home position.
ON
B Power Switch is turned ON.
Power Switch ON
Approx. 2~12
Approx. 0.5
ON/OFF
Fusing Heater Lamp
✽
The Fusing Unit temperature control is started.
C The Fusing Unit temperature reaches 210°C.
Fusing Thermistor 1 detects 210°C.