FrameMaker Ver.5.5E(PC) EP3000/EP3010 TROUBLESHOOTING
98.08.06
T-43
C0F## Sensor Malfunctions
✽
Code
Description
Detection Timing
✽
C0F02
Original Size Detecting
Board UN2 malfunction
In F7 mode:
•
The Busy signal does not go LOW within approx.
0.8 sec. after the initial signal has gone LOW, or
undefined data is input to the Master CPU.
•
The Busy signal does not go HIGH within approx. 5
sec. after the initial signal has gone LOW.
•
Under normal conditions:
The fixed-cycle pulse signal (Busy) remains HIGH or
LOW for 3 seconds or more.
•
Undefined data is input to the Master CPU.
When the Power Switch is ON:
•
The Busy signal remains HIGH or LOW for 5 sec-
onds or more.
•
Undefined data is input to the Master CPU.
C0F10
AE Sensor Board PWB-H
malfunction
Under normal conditions:
•
The output from PWB-H remains less than approx.
0.18V for a continuous 2-second period, with the
Exposure Lamp OFF, the Scanner at the home
position, and the Original Cover lowered.
In F5 mode:
•
The output from PWB-H is less than 1.8V when the
gain of the AE Sensor is 100%.
•
The output from PWB-H is 1.8V or more when the
gain of the AE Sensor is 0%.
•
The output from PWB-H is outside the target range
(1.8 ± 0.05V) when the gain of the AE Sensor is
50%.
F5 or FF for every 100 copies made:
•
The output from PWB-H does not fall within the tar-
get range (1.8 ± 0.05V) during adjustment proce-
dures by image stabilization control.
✽
C0F20
AIDC Sensor Board PWB-
G variation correction fail-
ure
In the initial F5 or FF mode, or F5 or FF for every 100
copies made:
•
The output from PWB-G is 1V or more when the
load resistance is made maximum by the 4-bit ana-
log switch.
•
The output from PWB-G is less than 1V when the
load resistance is made minimum by the 4-bit ana-
log switch.
•
The output from PWB-G does not fall within the
0.9V-1.1V range when the intensity of PWB-G’s
LED is varied.
✽
C0F22
AIDC Sensor Board PWB-
G VG correction failure
In the initial F5 or FF mode, or F5 or FF for every 100
copies made:
1. The grid voltage (VG) of 550V is output.
2. A solid black pattern is produced and the PWB-G
output is sampled.
3. The average of the above readings is 1.0V or less.