FrameMaker Ver.5.5E(PC) EP3000/EP3010 TROUBLESHOOTING
98.08.06
T-83
•
The message “Stabilizing Image Controller not run.” appears on the Touch panel
<Procedure>
4-4.
Miscellaneous
Condition
Detection Timing
T/C is less than 4% when an F5 operation is
run (initial adjustment).
•
When memory clear is run.
•
“PC Drum” of “Port/Option” counter is
cleared.
•
AIDC Sensor Board PWB-G develops a
malfunction.
Step
Check Item
Result
Action
1
Is “ATDC Current Level” of “Level
History” available from the Tech.
Rep. mode less than 4%?
YES
Run the auxiliary toner replenishing
cycle and then an F5 operation.
2
Run an F5 operation again.
—