FrameMaker Ver.5.5(PC) EP3000/EP3010 SWITCHES ON PWBs/TECH. REP. SETTINGS
98.05.29
S-6
<Clearing Procedures>
•
Initialize Points PJ29
1. Turn OFF the Power Switch.
2. With PJ29 closed, turn ON the Power Switch.
3. In approx. 5 sec. open PJ29.
4. Check that the message “Initialize completed” is shown on the Touch Panel, then touch
“OK.”
•
Memory Clear Test Point TP3
1. Turn OFF the Power Switch.
2. With the circuit across TP2 and 3 closed, turn ON the Power Switch.
3. In approx. 5 sec. open the circuit across TP2 and 3.
4. Check that the message “Memory Clear completed” is shown on the Touch Panel, then
touch “OK.”
NOTE
•
If an erratic operation or display occurs, perform the clearing procedures in the order of
PJ29 and TP3.
•
When memory clear has been performed, make the necessary settings again.
<List of Data Cleared by Switches and Points>
❍
: Cleared (initialized)
– : Not cleared:
Clearing Method
Data Cleared
Front Door
Open/Close
Trouble Reset
Switch
(S1)
Initialize
Switch
(PJ29)
Memory Clear
Test Point
(TP3)
Misfeed display
❍
❍
❍
❍
Malfunction display
(except Exposure Lamp
and fusing system)
❍
❍
❍
❍
Malfunction display (all
including Exposure Lamp
and fusing system)
–
❍
❍
❍
Erratic operation/display
–
–
❍
❍
User mode
–
–
–
❍
Service mode
–
–
–
❍
F5/F7 setting values
–
–
–
❍
System Input
–
–
–
❍
Accessory Test
–
–
–
❍
Level History
–
–
–
❍
Adjust mode
–
–
–
❍