FrameMaker Ver.5.5E(PC) EP3000/EP3010 DIS/REASSEMBLY, ADJUSTMENT
98.05.29
D-62
✽
Requirement
•
Setting value range: 42 to 58
•
Movement equivalent to 1 step of setting value: 0.75 mm
•
Having a greater setting value results in a greater erase width.
•
Having a smaller setting value results in a smaller erase width.
✽
Important
•
This adjustment must be made after the leading edge registration adjustment has been
completed.
(9) Adjustment of the Image Leading Edge Erase Width
•
Ready a test chart (A3 or 11"
×
17") as shown on the
left. Paint a 20 mm-long rectangle in black at the
center of the test chart along its leading edge as
shown. Adjust so that the erase width along the
leading edge of the painted area measures 1.0 to
6.5 mm.
1074D107
1. Place the test chart face down on the Original
Glass and align its rear left corner with the
marker on the Original Width Scale on the left side
of the platen.
Then, lower the Original Cover.
2. Make two single copies in full size mode (
×
1.000)
and check for leading edge erase width on the sec-
ond copy.
1139D043AB
3. Press the User Mode key, Meter Count key, Stop
key, 10-keys “0”, 10-keys “0”, Stop key, 10-keys “0”,
and 10-keys “1”, in that order, on the control panel
to set the copier into the Tech. Rep. mode.
4. Press the Stop key and then the Start key to set
the copier into the Factory Setting mode.
1149D086CA
5. Touch “Adjust” to open the “Adjust 1/2” menu, then
touch “Next” to access the “Adjust 2/2” menu.
6. Touch “ ” to highlight “A12 Leading Edge Erase
Adjust.”
1173D023CA