FrameMaker Ver.5.5E(PC) EP3000/EP3010 TROUBLESHOOTING
98.08.06
T-49
C0000
C0001
Step
Check Item
Result
Action
1
Does M9 turn?
Set the data of PWB-A (IC4A)
APC2 to “0.”
YES
Replace PWB-A.
2
Perform the “Controller Board
Check.” Is malfunction code
“C031B” displayed?
YES
Replace PWB-A.
NO
•
Check the drive coupling.
•
Replace M9.
Step
Check Item
Result
Action
1
Does M9 turn when the malfunction
is reset?
YES
Replace PWB-A.
2
Is malfunction code “C0001” dis-
played again?
YES
Replace PWB-A.