FrameMaker Ver.5.5E(PC) EP3000/EP3010 DIS/REASSEMBLY, ADJUSTMENT
98.05.29
D-71
1. Remove the Original Scales and Original Glass.
2. Install the Original Size Detecting Sensors (option).
(FD3)
(CD2)
3. Using pliers, reconnect jumper connector (J2) on Original Size Detecting Board as illus-
trated below.
4. After these steps have been completed, turn ON Power Switch and run the F7 opera-
tion.
•
For details, see “(4) Adjustment of the Original Size Detecting Board” on.
NOTE
•
Be sure to run the F7 operation after FD3 and CD2 have been installed or the copier is
unable to detect the paper size.
41
MISCELLANEOUS
41-1. INSTALLATION OF ORIGINAL SIZE DETECTING SENSORS
FD3/CD2 (OPTION; STANDARD FOR 200V AREAS)
•
Remove the harness cover (one screw).
•
Secure FD3 in position (one screw).
•
Connect the connector to FD3.
•
Reinstall the harness cover (one screw).
1149D046AA
•
Remove the cover from Original Size Detecting
Board (one screw).
•
Secure CD2 in position (one screw).
•
Pass the harness through the wiring saddle and
connect CN4 to Original Size Detecting Board.
1149D045AB
1149D048AA