© 2011 MIMAKI ENGINEERING CO.,LTD.
7.1.2
P.2
7.1.2 List of Error Messages
12
***** ERROR 12 *****
MAINTENANCE COMMAND
Other data than commands is received.
(This does not occur during the customer use.)
1. Clear the data of uncompleted printing.
2. Check the USB cable.
(specifications, cable length, etc.)
3.
Replacement of the Main PCB Assy (
16
***** ERROR 16 *****
MRL COMMAND
Received data does not follow the command
system set in the machine.
Send the data related to the class of commands,
using an application corresponding to this machine.
1. Make sure that the transmission data is in
MRL-III command system (data ripped for this
machine).
25
***** ERROR 25 *****
FULL-SPEED
USB2.0 interface occurred between the host PC
and the printer. (Full-Speed Mode connection)
Check whether the host PC is USB2.0 interface-
compliant or not. (Though the host PC can be used
in either case, use of Hi-Speed Mode connection is
recommended.)
30
***** ERROR 30 *****
OPERATION ERROR
Improper operations were performed on the
operation panel.
The operation cannot be carried out due to the
reason indicated in the second line.
Clear the corresponding error and carry out the
operation.
34
***** ERROR 34 *****
PRINT DATA REMAIN
Functional settings were changed or an inoperative
function was attempted while the machine has
already received data and printing of the data has
not been completed.
Print all the data received, or clear them all and
carry out the operation again from the start.
(If uncompleted printing data is remaining, provide
an account concerning the operating-condition
modification and the inoperative function.)
40
***** ERROR 40 *****
MOTOR ALARM X
Excessive load to the X-motor.
Turn off the main power, and turn it on a little later.
If the error occurs again, carry out the followings.
1. Check friction of X (Y) -axis motor.
2. Make sure that the media is not sticking.
(X OVER CURRENT)
3. Replace the X (Y)-axis motor.
4. Replace the regenerative resistivity PCB assy.
5.
Replacement of the Main PCB Assy (
41
***** ERROR 41 *****
MOTOR ALARM Y
Excessive load to the Y-motor.
42
***** ERROR 42 *****
X OVER CURRENT
Over current error of X-motor is detected.
43
***** ERROR 43 *****
Y OVER CURRENT
Over current error of Y-motor is detected.
45
***** ERROR 45 *****
CAPPING : PARAMETER
An error occurred in capping control.
(Improper parameter adjusted value)
Turn off the main power, and turn it on a little later.
If the error occurs again, carry out the followings.
1. Make sure that the adjusting value of
[#ADJUST] -> [CAPPING] is set correctly.
46
***** ERROR 46 *****
WIPER
An error occurred in wiper control.
Turn off the main power, and turn it on a little later.
If the error occurs again, carry out the followings.
1. Check that the wiper sensor functions properly
with [#TEST] -> [SENSOR TEST].
2. Check that the wiper motor functions properly
with [#TEST] -> [MOTOR TEST].
3. Check whether the guide rail of the wiper is not
clogged with ink. (Does the wiper move
smoothly?)
4. Replace the wiper sensor.
5. Replace the step motor.
6. Replace the station PCB assy.
List of Error Messages (2/4)
Error
No.
Indication on LCD
Cause
Remedy
R.1.0
MAINTENANCE MANUAL > Troubleshooting > Details on Errors and Malfunctions > List of Error Messages
Model
TS34-1800A
Issued 2011.10.17 Revised
F/W ver
1.20
Remark
1.0