5.1.8 [MOTOR TEST] XY SERVO MOTOR
Function
Operation test of XY-axis motor is executed.
Operation Procedures
Step
Item
Description
Remarks
1
X speed designation
[
], [
] : Selects speed.
Set value: 1 – 500 mm/s (unit: 1 mm/s)
[
], [
] :
Selection of items 1 – 3
[ENTER]:
Transits to the Y direction
setting (5 –).
2
X acceleration designation
[
], [
] : Selects acceleration.
Set value: 0.01 – 2.00 G (unit: 0.01 G)
3
X moving amount
designation
[
], [
] : Selects moving amount.
Set value: 1 mm – paper length (unit: 1 mm)
When media is not detected: 1 mm – 2500 mm
Press [ENTER] to start Y-axis motor setting.
4
Y speed designation
[
], [
] : Selects speed.
Set value: 1 – 1500 mm/s (unit: 1 mm/s)
[
], [
] :
Selection of items 4 – 6
[ENTER]:
Transits to the following
step.
[END]: Transits to the X
direction setting (2 –).
5
Y acceleration designation
[
], [
] : Selects acceleration.
Set value: 0.05 – 2.00 G (unit: 0.05G)
6
Y moving amount
designation
[
], [
] : Selects moving amount.
Set value: 1 mm – paper width (unit: 1 mm)
When media is not detected: 1 mm – Mechanical
limit size
7
Cap OFF
Only after media detection
8
Test start
[ENTER]: Repeats the following motion with the designated
conditions.
(During the motion, No. of Y reciprocation is
displayed.)
a) Moves by Y designated distance.
b) Moves by X designated distance, and moves to Y
starting position.
9
End
[END] :Returns to the motion starting position and executes
capping to end the test.