7.1.2
P.3
7.1.2 List of Error Messages
50
***** ERROR 50 *****
MEDIA DETECT
Paper could not be detected.
Turn off the main power, and turn it on a little later.
If the error occurs again, carry out the followings.
1. Make sure that there is enough clearance
between the platen and the end of the P rubber.
2. Check the sensor value for when there is media
and when there is no media using [#TEST] ->
[PAPER SENSOR].
If the difference is ±50, detection is possible.
If the difference is not ±50, execute the
following.
3. Make sure that the rear paper sensor is working
correctly using [#TEST] -> [SENSOR TEST]
-> [REAR PAPER].
4. Clean the rear paper sensor and adjust its
mounting position, or replace it.
5.
51
***** ERROR 51 *****
Y-ORIGIN
Y-origin could not be detected.
Turn off the main power, and turn it on a little later.
If the error occurs again, carry out the followings.
1. Check that the Y-origin sensor functions
properly with [#TEST] -> [SENSOR TEST].
2. Replace the Y-origin sensor.
3.
70
E70 FPG4
FPGA Configuration fails.
(This does not occur during the customer use.)
1.
Replacement of the Main PCB Assy (
71
E71 SD-RAM
Abnormal operation in SD-RAM.
(This does not occur during the customer use.)
1. Make sure that PRAM PCB assy is connected
properly.
2.
3.
Replacement of the Main PCB Assy (
74
E74 TRANS DATA
Received data is not Version Up file
(This does not occur during the customer use.)
1. Make sure that the ROM file is transmitted.
80
E80 ROM0 ERASE
ROM0 Erase error
(This does not occur during the customer use.)
1.
Replacement of the Main PCB Assy (
81
E81 ROM1 ERASE
ROM1 Erase error
82
E82 h'********
ROM0 Write error
83
E83 h'********
ROM1 Write error
84
E84 h'********
Verify error
85
E85 ROM HASH
Hash check error
90
E90 h'********
ROM Erase error
92
E92 h'********
ROM Write error
95
E95 MODE SHIFT
Transition to the version up mode is not allowed.
99
E99 VERSION DATA
Wrong version data
120
**** ERROR 120 ****
ENVIRONMENT TEMP (LO)
The ambient temperature is outside of the warranty.
(The temperature is too low.)
Adjust the ambient temperature of the machine.
(To continue operation without changing the
ambient conditions, press the [ENTER].)
Operation under the temperature among the
guaranteed operation temperature range is
recommended.
121
**** ERROR 121 ****
ENVIRONMENT TEMP (HI)
The ambient temperature is outside of the warranty.
(The temperature is too high.)
144
**** ERROR 144 ****
CARTRIDGE SET!
There are slots where cartridges are not inserted.
Insert cartridges into the slots, since the slots may
dry up when left without them inside and the ink
may become unusable.
Give instruction (to the customers) that, when they
leave the slot without cartridge in it, its needle may
dry up and becomes unable to absorb the ink.
ERROR COMMAND
(This does not occur during the customer use.)
1. Check the USB cable.
(specifications, cable length, etc.)
List of Error Messages (3/4)
Error
No.
Indication on LCD
Cause
Remedy
R.1.0
MAINTENANCE MANUAL > Troubleshooting > Details on Errors and Malfunctions > List of Error Messages
Model
TS34-1800A
Issued 2011.10.17 Revised
F/W ver.
1.20
Remark
1.0