© 2011 MIMAKI ENGINEERING CO.,LTD.
4.2.3
P.4
4.2.3 [HEAD ADJUST] AVERAGING ADJUST
Stagger Adjustment
1. Carry out the slant adjustment through the following proce-
dures.
As shown in the diagram on the left, patterns of columns "a"
and columns "b" are printed alternately at a pitch width of
approximately 100 mm. The discrimination between columns
"a" and columns "b" is performed by the magenta and cyan
strips (indicated by the thick red arrows in the diagram on the
left) printed over the respective patterns at the top of head 1.
These strips indicate that magenta is column "a" and cyan is
column "b".
Check the stagger of each column.
Adjust it so that 4 nozzles each for both edges of the head to
be adjusted may be overlapped in alignment in the X
direction.
P
e
r
f
o
r
m
a
n
a
v
e
r
a
g
i
n
g
a
d
j
u
s
t
m
e
n
t
.
Perform an averaging adjustment.
Adjust it so that 4 nozzles each for both edges of column “a”
and column “b” may be overlapped on average in the X
direction.
It is necessary to perform SLANT adjustment before STAGGER adjustment.
After adjusting the stagger, adjust the slant.
Columns “b”
M
C
C
M
Columns “a”
Columns “a”
Columns “b”
Columns “b” Columns “a”
Stagger confirmation point
Overlap of dots between the heads is 4 dots.
<Scope Image>
<Adjustment Example>
Columns “b”
Columns “a”
R.1.0