© 2011 MIMAKI ENGINEERING CO.,LTD.
4.2.2
P.2
4.2.2 [HEAD ADJUST] STAGGER ADJUST
2. Select [STAGGER ADJUST] from the operation menu to
execute adjustment pattern drawing.
3. Move the head over the platen using the JOG key.
4. Carry out the stagger adjustment through the following
procedures.
There is a gap at the right end of pattern on the joint of each
head. Adjust it using this gap.
Check the stagger of each column.
Check that the distance between the Head 1 and 2 is about
140µm.
< L O C A L . 1 >
[#01]
F U N C T I ON
# A D J U S T
<ENT>
# A D J U S T
H E A D A DJ U S T
<ent>
# H E A D AD J U S T
S T A G G E R A D J U S T <ent>
# S T A G G ER A D J U S T
P R I N T ST A R T
:ent
[FUNCTION]
Adjustment pattern
drawing
Stagger confirmation point
Head 1
Head 2
<Scope Image>
Rotate the adjustment
lever counter-clockwise.
The position of Head 2
moves backward.
Rotate the adjusting
screw clockwise. The
position of Head 2 moves
forward.
約
140
μ
m
Head 1
Head 2
Head 1
Head 2
Head 1
Head 2
There is no overlap of dots between the heads.
R.1.0
MAINTENANCE MANUAL > Adjustment Items > Adjustment Function > [HEAD ADJUST] STAGGER ADJUST
Model
TS34-1800A
Issued 2011.10.17 Revised
F/W ver.
1.20
Remark
1.0