© 2011 MIMAKI ENGINEERING CO.,LTD.
6.3.1
P.1
MAINTENANCE MANUAL > Disassembly and Reassembly > Drive System > X-axis Motor Assy
Model
TS34-1800A
Issued 2011.10.17 Revised
F/W ver
1.20
Remark
1.0
6.3.1 X-axis Motor Assy
Work procedures
1. Remove the following covers.
•
Mainte Cover L
•
Left Cover
2. Remove the screws (x2) attached to the XM bracket.
3. Remove the X-axis motor connector.
4. Remove the spring, and remove the XM bracket and X-axis
motor from the main unit.
Turn the main power OFF when turning the power OFF. It is very dangerous if sleep mode functions
mistakenly during the operation.
X-axis Motor
X-axis motor
XM bracket
R.1.0