© 2011 MIMAKI ENGINEERING CO.,LTD.
1.1.5
P.1
R.1.0
1.1.5 Power OFF
Indication on LCD
Processing sequence
Processing during sub-power OFF
Processing during main-power OFF
Step
Processing
Description
Indication
on LCD
1
Hardware resources OFF
1. Turn off the dry fan, exhaust fan, and vacuum fan.
2. Turn off the output of the COM waveform.
2
Turning off solenoids
1. Turn off the cartridge valve solenoid.
3
Saving parameters
1. Save parameter values of system parameter, running parameter, etc.
2. Update head ID and Print head memory.
4
Motor OFF
1. Turn off servo and drive motor power.
5
Sub-power LED blinking
1. Indicates sub-power off by sub-power LED blinking.
6
Power OFF
Step
Processing
Description
1
Saving parameters
1. Save the running parameter values.
In service mode, the buzzer sounds when the parameter values have been stored successfully.
Turn off sub-power to implement the sleeve operation for the prevention of the clogged ink during
power OFF.
When turning off main power, turn off sub-power first and then main power.
Display at sub switch power OFF
PL E A S E WA I T
P O W E R OF F
MAINTENANCE MANUAL > Operating Principle > Basic Operation > Power OFF
Model
TS34-1800A
Issued 2011.10.17 Revised
F/W ver.
1.20
Remark