© 2011 MIMAKI ENGINEERING CO.,LTD.
4.2.3
P.2
4.2.3 [HEAD ADJUST] AVERAGING ADJUST
Slant Adjustment
1. Carry out the slant adjustment through the following proce-
dures.
As shown in the diagram on the left, patterns of columns "a"
and columns "b" are printed alternately at a pitch width of
approximately 100 mm. The discrimination between columns
"a" and columns "b" is performed by the magenta and cyan
strips (indicated by the thick red arrows in the diagram on the
left) printed over the respective patterns at the top of head 1.
These strips indicate that magenta is column "a" and cyan is
column "b".
Check the slant of each column.
For the columns “b”, the relationship between the points of
impact and the slant of the head is as shown in the diagram
on the left.
For the columns “a”, the pattern is reversed.
Perform an averaging adjustment.
The standard color for each column is M for columns “a”
and C for columns “b”.
Move the adjustment lever and adjust the slant.
In the diagram on the left, the columns “b” are aligned while
the columns “a” are misaligned. In this case, move “b”
columns slightly so that the degrees of scattering of “a” and
“b” columns are equal. (=Intermediate adjustment)
Columns “b”
Slant confirmation point
M
C
C
M
Columns “a”
Columns “a”
Columns “b”
Columns “b” Columns “a”
Overlap of dots between the heads is 4 dots.
<Actual Image>
<Scope Image>
When tilted towards the back right
(move the adjustment lever in the
clockwise direction)
When tilted towards the front right
(move the adjustment lever in the
anti-clockwise direction)
<Adjustment Example>
Columns “b”
Columns “a”
R.1.0
MAINTENANCE MANUAL > Adjustment Items > Adjustment Function > [HEAD ADJUST] AVERAGING ADJUST
Model
TS34-1800A
Issued 2011.10.17 Revised
F/W ver.
1.20
Remark
1.0