© 2011 MIMAKI ENGINEERING CO.,LTD.
8.4.2
P.1
R.1.0
MAINTENANCE MANUAL > Operation Flow > Service Mode > #TEST
Model
TS34-1800A
Issued 2011.10.17 Revised
F/W ver
1.20
Remark
1.0
8.4.2 #TEST
#CHECK PATTERN
PATTERN:100%
DPI:540x1080 PAS:3
SCN:Bi SPD:x1 WF:3
#CHECK PATTERN
PATTERN :COLOR CHART
DPI
:540x720
SCAN:Uni-D / PASS:6
X=1000 Y=1000
DENSITY
:ALL
#TEST
CHECK PATTERN
<ent>
FUNCTION
#TEST
<ENT>
HED:12__ CL:K___
X=20 Y=1000
#CHECK PATTERN
PATTERN:DROP.POS CHK
DPI
:540x720
SCAN:Uni-D:/ PASS:6
X=1000 Y=1000
#CHECK PATTERN /100%
PRINT START :ent
540x720.V6. 6P,Uni
x1.H1
0.00m
DPI: 540x720.PAS: 6
SCN:Uni SPD:x1 WF:6
HED:1 CL:MBYK1234
X=10 Y=10
#TEST
ALL PATTERN
<ent>
#ALL PATTERN
PRINT START
:ent
Pattern drawing
#TEST
MOTOR TEST
<ent>
#MOTOR TEST
X SERVO MOTOR
<ent>
#X SERVO * RUNNING *
COUNT = 0
#X SERVO MOTOR
S= 500 A=0.50 X=1000
#MOTOR TEST
Y SERVO MOTOR
<ent>
#Y SERVO * RUNNING *
COUNT = 0
#Y SERVO MOTOR
S= 500 A=0.50 X=1000
#MOTOR TEST
XY SERVO MOTOR <ent>
#XY servo* RUNNING *
COUNT = 0
S= 500 A=0.50 X=1000
S= 500 A=0.50 X=1000
#MOTOR TEST
WIPER MOTOR
<ent>
#WIPER * RUNNING *
COUNT = 0
SPEED :WAIT :COUNT
100 : 0 :CONT.
#WIPER * RUNNING *
100 : 0 :CONT.
#MOTOR TEST
PUMP MOTOR
<ent>
#PUMP MOTOR
COUNT = 0
#PUMP MOTOR
SPD=1200 DIR=FORW.
<CARRIDGE>:< MOTOR >
IN : OFF
S= 500 A=0.50 X=1000
S= 500 A=0.50 X=1000
#Y SERVO * RUNNING *
S= 500 A=0.50 X=1000
#X SERVO * RUNNING *
S= 500 A=0.50 X=1000
#MOTOR TEST
TAKE-UP MOTOR
<ent>
#TAKE-UP MOTOR
*** RUNNING ***
#TAKE-UP MOTOR
START
:ent
[
]/ [
]: Modifies the compensation value.
[ENTER]: Finalizes (To the next compensation screen)
∗
Subsequently, 50%, 25%, 12.5%, 6.25%,
nozzle check can be selected (Omitted).
JOG permitted
[FUNCTION],
[
] / [
]
[FUNCTION],
[
] / [
]
[
] / [
]
[
] / [
]
[
] / [
]
[
] / [
]
[
] / [
]
[
] / [
]
[
] / [
]
[
] / [
]
[FUNCTION]
[FUNCTION]
[
] / [
]: Changes condition display.
[
] / [
]: Changes condition display.
[
] / [
]: Changes condition display.
[
] / [
]: Changes condition display.