© 2011 MIMAKI ENGINEERING CO.,LTD.
6.4.1
P.1
6.4.1 Power Supply PCB Assy
Work procedures
1. Turn off the main power supply and remove the power plug
from the main body.
2. Remove the
power unit box cover
.
3. Disconnect all connectors on PCB.
4. Remove the screws and then remove the
power supply PCB
assy
.
5. Reverse the disassembly procedure for reassembly.
After turning off the sub and main power switches, unplug the power cord. Make sure to take 15 minutes
before restarting the operation. It is very dangerous if sleep mode functions mistakenly during the
operation.
Moreover, the PCB may be damaged in case electric charge still remains inside.
Also, there is a possibility of electric shock because of high power voltage applied to the high-pressure
part of the power supply PCB assy. Take care to avoid contact with it.
Power Supply PCB Assy
Screw
Before mounting the power unit box cover, adjust the
voltage of the power supply PCB assy.
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Electrical Parts > Power Supply PCB Assy
Model
TS34-1800A
Issued 2011.10.17 Revised
F/W ver
1.20
Remark
1.0
Power Supply PCB Assy