200
**** ERROR 200 ****
HEAD MEMORY (----)
An error occurred in head unit memory.
Turn off the main power, and turn it on a little later.
If the error occurs again, carry out the followings.
1. Check the mini memory cable.
2. Replace the mini memory.
3.
4.
Replacement of the Main PCB Assy (
202
**** ERROR202 ****
DEVICE CONSTRUCTION
Head unconnected.
An error occurred in slider PCB.
203
**** ERROR 203 ****
SDRAM SIZE
The machine is not provided with the required size
of SD-RAM.
Turn off the main power, and turn it on a little later.
If the error occurs again, carry out the followings.
1.
205
**** ERROR 205 ****
42V HEAD VOLTAGE
An excessive current flowed in the circuit of the
print head, and the fuse was blown.
7.2.1 Electrical Troubleshooting
, and
replace the following parts if it has damaged.
• Check the head FFC cable.
• Replace the head.
•
Replacement of the Main PCB Assy (
• Replace the fuse. (Main PCB F13)
•
• Replace the fuse. (HDC PCB F3)
207
∗∗∗∗
ERROR 207
∗∗∗∗
SLEW RATE
Trouble with COM wave
1. Restart
2. Upload event log
3. Report what it happened to
SIGN&GRAPHIC, development department
∗∗∗∗
ERROR 207
∗∗∗∗
OVERFLOW
∗∗∗∗
ERROR 207
∗∗∗∗
UNDERFLOW
208
**** ERROR 208 ****
CHECK MAIN PCB ID XX
The device type ID of the main PCB is different.
(“XX” is the ID code of the PCB.)
Check the device type ID switch of the main PCB.
250
**** ERROR 250 ****
Y COORDINATES
An error was detected during scanning operation. Turn off the main power, and turn it on a little later.
If such an abnormality recurs, check the uploaded
parameter and the status of use, then report them to
the Development Division.
251
**** ERROR 251 ****
SYSTEM ERROR
System error
Turn off the main power, and turn it on a little later.
If the error occurs again, carry out the followings.
1. Check whether no abnormality is found by
examining the memories (Main.FROM and
32m SDRAM).
2. In case the error recurs, check the uploaded
parameter and the status of use, and then report
them to the Development Division.
List of Error Messages (4/4)
Error
No.
Indication on LCD
Cause
Remedy
R.1.0
MAINTENANCE MANUAL > Troubleshooting > Details on Errors and Malfunctions > List of Error Messages
Model
TS34-1800A
Issued 2011.10.17 Revised
F/W ver
1.20
Remark
1.0