© 2011 MIMAKI ENGINEERING CO.,LTD.
5.1.20
P.1
R.1.0
5.1.20 SKEW CHECK
Function
Skewing of media is checked.
When media is not detected, an OPERATION ERROR (ERROR30) is displayed.
Feed distance is designated to execute feeding.
Feed distance: 1–500 m (unit: 1 m)
During the feeding, remaining of feed distance is displayed with unit of 10 mm.
[END]: Aborts feeding, [ENTER]: Restarts feeding.
Cut jig function
After the Skew check starts (feed distance is not designated), the following operation starts the cut jig function.
[REMOTE] -> [FUNCTION]
The cut jig function repeats media cut
→
feed in feed distance and number of cut times designated.
Number of cut times is displayed in count down during cut.
Feed distance
: 10–10000 mm (unit: 10 mm, Default 500 mm)
Number of cut times : 1–1000 count (unit: 1 count, Default 25 count)
MAINTENANCE MANUAL > Test Items > Test Function > SKEW CHECK
Model
TS34-1800A
Issued 2011.10.17 Revised
F/W ver
1.20
Remark
1.0