Page 7-10
|
Section 7.2: Replacing Components
9. Install the new thermocouple with all
the spacers in the sequence shown.
Make sure the thermocouple is inserted
all the way.
10. Tighten the thermocouple nut.
11. Reinsert the fiberglass insulation and
bottom cover with screws.
12. Install both thermocouple wire mounts.
13. Install the nozzle and clamp. Make
certain to install the clamp with the
ring side up.
14. Plug in the thermocouple leads, wire #1
to red, and wire #2 to yellow.
Module 7.2.2: Heater Rely
The Heater Relay acts as an interpreter between the Thermocouple and the
Temperature Controller. Generally the Heater Relay will last several years. The
Heater Relay should be replaced if the machine is experiencing erratic
temperatures on the Temperature Controller or The Heat Elements are burning
out prematurely.
Warning!
Only a qualified technician may perform any maintenance on
machine. This may be a Miller Weldmaster representative or someone
trained by a Miller Weldmaster representative.
Summary of Contents for T-100