Page 7-1
|
Section 7.1: Maintenance
Section 7.1: Maintenance
WARNING!
Only a qualified technician may perform maintenance on this machine.
This may be a Miller Weldmaster representative or someone trained by a
Miller Weldmaster representative.
WARNING!
Machine must be disconnected from power source before any maintenance
may begin.
Module 7.1.1: Cleaning The Air Filter Cartridge
The Miller Weldmaster T-500 and T-100 have an internal air compressor that
supplies airflow to the heat elements. Periodic cleaning and changing of the Air
Filter Cartridge is necessary to maintain sufficient airflow. Insufficient airflow
or any impurities in the airflow will shorten the life of the heat elements.
Clean Air Filter Cartridge Every Week
If the surrounding conditions in your production area are not clean, it is
recommended that you clean the Air Filter Cartridge twice a week.
1. Turn the Circuit Breaker to the off
position.
2. Disconnect the power cord from the
power supply. If the power cord is
wired into the power supply, turn the
power off at the junction box.
3. Unlock the front cabinet door and open.
4. Loosen and remove the Air Filter
Cartridge End Cap.