![Miller Weldmaster T-100 Manual Download Page 21](http://html.mh-extra.com/html/miller-weldmaster/t-100/t-100_manual_1796794021.webp)
Page 2-6
Chapter 2: Heating System Overview and Adjustments
|
Section 2.1: Hot Air Heating System
Nozzle Left/Right Alignment
The left/right alignment is the horizontal relationship the Nozzle has with the Weld
Rollers. The center of the Nozzle must be placed directly in the center of the Weld Rollers.
Having the Nozzle shifted to one side or the other will result in the weld being shifted to
the side that the Nozzle is favoring leaving the opposite side unwelded. Depress the Drive
Foot Switch to swing the Nozzle into place and check the left/right alignment. If not
properly placed,
(Figure2.14)
release the Drive Foot Switch to swing the Nozzle out and
proceed with the following:
1. Adjust the left/right alignment so that the
Nozzle is centered on the weld rollers, by
turning the Left/Right Nozzle Adjustment
Knob.
(Figure2.15)
a. clockwise to adjust the Nozzle to the
left
b.counterclockwise to adjust the
Nozzle to the right
2. Depress the Drive Foot Switch to swing the
Nozzle into place and Check to see if the
proper adjustment of Nozzle has been
made.
(Figure2.16)
Repeat steps 1 and 2
until correct
Figure 2.14:
Figure 2.15:
Figure 2.16:
Summary of Contents for T-100