Page 7-6
|
Section 7.2: Replacing Components
Module 7.2.1: Heat Elements
The Heating Elements used by the Miller Weldmaster T-500 and T-100are
rated for 1000 hours of use at 1000 degrees F (537 degrees C). Although longer
heat element life is possible with proper maintenance, 1000 hours is the
average. If the Heat Elements fail prematurely, contact a Miller Weldmaster
representative before replacement. It is recommended that both elements be
changed even if only one burns out.
1. Turn the Service Disconnect to the off
position.
2. Disconnect the power cord from the
power supply. If the power cord is
wired into the power supply, turn the
power off at the junction box.
3. Remove the 3 sheet metal screws from
the top of the element housing.
4. Carefully unplug the 2 Thermocouple
leads, being careful not to pull the
wires out of the leads.
5. Remove the top covering of the element
housing and slide it out of the way.
6. Remove the 2 pieces of insulation
between the wire leads and the
aluminum air divider.