Plumbing
120
– Install the filter (supplied in accessory pack) between the stopcock
valve and the inlet hose
(see illustration in "Maintenance, Clean the water intake filters").
Do
NOT
shorten or otherwise damage the inlet hoses (see
diagram).
See installation diagram supplied.
AD water
connection
This dishwasher is supplied as standard for a pressurised system
operating between 30 and 1000 kPa. If the water pressure is below
140 kPa the water intake duration will be automatically increased.
Connect the AD inlet hose (green coded hose) with 3/4 inch
threaded union to the onsite stopcock for AD water.
If AD water connection is not needed, this option can be switched
off during the commissioning process or the dishwasher controls
can be reprogrammed by Miele Service. The AD inlet hose remains
connected to the dishwasher.