5.3.7.2
Hold Time
Extending the hold time of a detection result beyond the actual duration of the color match is useful if the ac-
tuators controlled by the color measuring system require a certain minimum hold time of the switching level
or the measurement is faster than the reaction time of the downstream evaluation unit.
The hold time can be set to one of three different stages in the option menu.
Stage
Hold Time
Description of LED display
1
0 ms
1x flashing with 150 / 150 ms, followed by 900 ms off = 1200 ms
2
10 ms
2x flashing with 150 / 150 ms, followed by 600 ms off = 1200 ms
3
1000 ms
3x flashing with 150 / 150 ms, followed by 300 ms off = 1200 ms
INT
OPT
ESC
TOL
CLR
TEACH
AUTO
1
2
3
4
5
6
7
8
OPTIONS
OUT / LE
VEL
GATE
TEACH
HOLD
MULTI
CLASSIFY
CYLINDER
SPHERE
BOX
Press the
key for less than 2 sec. to select the option group.
INT
OPT
ESC
TOL
CLR
TEACH
AUTO
1
2
3
4
5
6
7
8
OPTIONS
OUT / LE
VEL
GATE
TEACH
HOLD
MULTI
CLASSIFY
CYLINDER
SPHERE
BOX
Press the
TEACH
key for less than 2 sec. to activate the hold time for all
outputs.
The activated hold time is signaled by the associated LED flashing.