Page 34
Installation and Assembly
colorSENSOR CFO
Model CFO200
Pin Color
CAB-M12-8P-St-ge
Function Description
Comment
1
White
IN1
Configurable trigger input,
reading trigger, teach color,
teach color as new group,
add color to current group,
continuously teach and
group colors, delete color
table, automatic controller
sensitivity adjustment, white
balance, key lock
Not electrically separated, compara-
tor input with threshold at
V
+
/2 ±5 %,
low level <
V
+
/2 ±5 %,
high level >
V
+
/2 ±5 %
(max. 30 V), internal pull-down resis-
tor, open input is recognized as low.
2
Brown
IN2
3
Green
IN3
Switching input not electrically separated, open input recognized as low.
Comparator input with threshold at
V
+
/2 ±5 %
Low Level
<
V
+
/2 ±5 %
High Level
>
V
+
/2 ±5 % (max. 30 V)
i
Switching levels always refer to
V
+
(10 V - 28 V) for all inputs.