Page 50
Operation
colorSENSOR CFO
5.3.4
Color Management
After having installed and adjusted the color measuring system
, you can now teach colors or color
groups for the recognition task.
INT
OPT
ESC
TOL
CLR
TEACH
AUTO
1
2
3
4
5
6
7
8
OPTIONS
OUT / LE
VEL
GATE
TEACH
HOLD
MULTI
CLASSIFY
CYLINDER
SPHERE
BOX
Press the
TEACH
key for longer than 2 sec.
You are now in the
TEACH
(color teach) menu.
INT
OPT
ESC
TOL
CLR
TEACH
AUTO
1
2
3
4
5
6
7
8
OPTIONS
OUT / LE
VEL
GATE
TEACH
HOLD
MULTI
CLASSIFY
CYLINDER
SPHERE
BOX
The switching outputs of the selected recognition groups flash rhythmically. The
flashing rate indicates the status of the current recognition group.
- Medium-fast flashing indicated that the current recognition group contains no
colors (1-pulse period 100/900 ms).
- Fast flashing indicates that the recognition group comprises at least one color.
However, the latter is not being recognized (2-pulse periods (50/50/50/850
ms).
- Slow flashing indicates that one color of the recognition group is being recog-
nized (nearly continuous illumination 900/100 ms).
All color groups or switching outputs to the color groups can be selected indi-
vidually by pressing the arrow key